髌骨骨折不同改良方式张力带钢丝固定的生物力学研究及临床应用
摘要点击次数: 2511   全文下载次数: 1142   投稿时间:2000-12-22    
作者Author单位AddressE-Mail
郑季南 ZHENG Ji-nan 解放军第180医院,福建泉州362000 The 18th Hospital of PLA Fujian Quanzhou ,362000  
徐新华 XU Xin-hua 解放军第180医院,福建泉州362000 The 18th Hospital of PLA Fujian Quanzhou ,362000  
洪庆南 HONG Qing-nan 解放军第180医院,福建泉州362000 The 18th Hospital of PLA Fujian Quanzhou ,362000  
王森林 解放军第180医院,福建泉州362000 The 18th Hospital of PLA Fujian Quanzhou ,362000  
曹杰 解放军第180医院,福建泉州362000 The 18th Hospital of PLA Fujian Quanzhou ,362000  
方钧 解放军第180医院,福建泉州362000 The 18th Hospital of PLA Fujian Quanzhou ,362000  
期刊信息:《中国骨伤》2002年,第15卷,第4期,第208-210页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:
中文摘要:

目的:为临床选择有效的骸骨骨折内固定方式提供实验依据。

方法:取4具外伤截肢后下肢,保留股四头肌健、骸骨、骸韧带及关节囊,将股骨、腔骨固定在材料试验机上,维持腔股关节屈曲36”位,通过牵拉肌腥产生张力,用线性运动传感器测定骨折移位,移位3rum为固定失效,测AO张力带钢丝、昏氏张力带钢丝、“8”字张力带钢丝和Magnt,&x)tl钢丝4种固定法。

结果:“8”字张力带钢丝和肯氏张力带钢丝固定效果最好,AO张力带钢丝次之,三者均能承受294N以上牵张力,允许术后早期活动,M哪~~钢丝不能承受294N以上牵张力,固定欠可靠。临床应用“8”字张力带钢丝固定治疗骸骨骨折42例,其中横断骨折36例,粉碎性骨折6例,随访6~26个月,优良率达95.2%。

结论:克氏针“8”字张力带钢丝固定是治疗骸骨骨折首选方法,其固定效果可靠,疗效高。
【关键词】骨折固定术,内  髌骨骨折  生物力学
 
Biomechanical evaluation and clinical application of various forms of modified tension band wiring for the treatment of patellar fracture
ABSTRACT  

Objective:provide experimental relevant data of internal fixation method for the effec-tive treatment of patellar fracture

Methods:Four amputation lower limb specimens were used in the experi-ment study. The tendon of quadriceps femoris,patella,patellar ligament and articular capsule of the four limbs were kept intact. The femur and tibia were fixed in an Instron Materials Testing System,and the tibiofemoral joint was held at 36?of flexion. Tension was applied to the patella through the quadriceps tendon and fracture displacement was measured with linear motion transducers. Displacement of 3mm was considered to represent failure of fixation. AO tension band wiring,Xu’s tension band wiring,figure of eight tension band wiring and Magnusson wiring were examined respectively.

Results:The figure of eight and Xu’ s tension band wiring were more effective than AO tension band wiring. All of them could bear tensive force over 294N and may pro-vide sufficient fixation to allow immediate range of motion. Magnusson wiring could bear force less than 294N, which appeared not firm enough. Accordingly, 42 cases of patellar fracture were treated with figure of eight tension band wiring, the excellent and good Results was 95.2% at follow-up studies ranged from 6 to 26 months.

Conclusion: Figure of eight tension band wiring should be selected at first in the treatment of fracture of patella for its effective fixation.
KEY WORDS  Fracture fixation,internal  Patellar fracture  Biomechanics
 
引用本文,请按以下格式著录参考文献:
中文格式:郑季南,徐新华,洪庆南,王森林,曹杰,方钧.髌骨骨折不同改良方式张力带钢丝固定的生物力学研究及临床应用[J].中国骨伤,2002,15(4):208~210
英文格式:ZHENG Ji-nan,XU Xin-hua,HONG Qing-nan.Biomechanical evaluation and clinical application of various forms of modified tension band wiring for the treatment of patellar fracture[J].zhongguo gu shang / China J Orthop Trauma ,2002,15(4):208~210
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号