人工肱骨头置换治疗肱骨近端4部分骨折及骨折脱位
摘要点击次数: 2138   全文下载次数: 1894   投稿时间:2007-09-25    
作者Author单位AddressE-Mail
沈是铭 SHEN Shi-ming 宁波镇海医疗中心龙赛医院骨科,浙江 宁波 315200 Department of Orthopaedics,Zhenhai Medical Center,Longsai Hospital of Ningbo,Ningbo 315200,Zhejiang,China shiming88@nbip.net 
毛宾尧 MAO Bin-yao 宁波大学附属宁波第一医院骨科  
王毳 WANG Cui 宁波大学附属宁波第一医院骨科  
黄涛 HUANG Tao 宁波大学附属宁波第一医院骨科  
贾学文 JIA Xue-wen 宁波大学附属宁波第一医院骨科  
高林山 GAO Lin-shan 宁波镇海医疗中心龙赛医院骨科,浙江 宁波 315200 Department of Orthopaedics,Zhenhai Medical Center,Longsai Hospital of Ningbo,Ningbo 315200,Zhejiang,China  
陈永坚 CHEN Yong-jian 宁波镇海医疗中心龙赛医院骨科,浙江 宁波 315200 Department of Orthopaedics,Zhenhai Medical Center,Longsai Hospital of Ningbo,Ningbo 315200,Zhejiang,China  
期刊信息:《中国骨伤》2008年,第21卷,第5期,第387-389页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:
中文摘要:

目的:探讨应用人工肱骨头置换治疗肱骨近端4部分骨折及骨折脱位的近期疗效。

方法:25例肱骨近端4部分骨折及骨折脱位的患者,男11例,女14例;年龄56~77岁,平均68.2岁;均行人工肱骨头置换治疗。应用Neer疗效评分系统,根据患者疼痛、功能、肩关节活动范围评价术后疗效。

结果:术后随访12~40个月,平均29.3个月。所有病例术后均无感染、神经损伤、假体周围骨折、假体松动、脱位等并发症。Neer评分优8例,良11例,可6例,优良率76%.

结论:通过标准的手术操作及术后积极合理的康复锻炼,人工肱骨头置换治疗肱骨近端4部分骨折及骨折脱位近期疗效满意。
【关键词】肱骨骨折  肩脱位  关节成形术,置换
 
Replacement of humeral head prosthesis for four-part proximal humeral fractures or fracture-dislocations
ABSTRACT  

Objective: To evaluate the short-term results of humeral head replacement for the treatment of four-part proximal humeral fractures or fracture-dislocations.

Methods: Twenty-five patients(11 male and 14 female)with four-part proximal humeral fractures or fracture-dislocations underwent humeral head replacement. The average age was 68.2 years (ranging from 56 to 77 years). All cases were followed up and evaluated the clinical results including pain,function and range of motion of shoulder with Neer scoring system.

Results: The follow-up ranged from 12 to 40 months with an average time of 29.3 months. No prosthesis loosening,prosthesis dislocation,postoperative infection,nerve injury or periprosthesis fractures occurred. The results were excellent in 8 cases,good in 11 cases and fair in 6 cases. The excellent and good rate was 76% according to Neer scoring system.

Conclusion: Replacement of humeral head prosthesis could attain good short-term results for four-part proximal humeral fractures or fracture-dislocations. The key to improve the postoperative results is meticulous surgical techniques and appropriate correct consecutive physical therapy.
KEY WORDS  Humeral fractures  Shoulder dislocation  Arthroplasty,replacement
 
引用本文,请按以下格式著录参考文献:
中文格式:沈是铭,毛宾尧,王毳,黄涛,贾学文,高林山,陈永坚.人工肱骨头置换治疗肱骨近端4部分骨折及骨折脱位[J].中国骨伤,2008,21(5):387~389
英文格式:SHEN Shi-ming,MAO Bin-yao,WANG Cui,HUANG Tao,JIA Xue-wen,GAO Lin-shan,CHEN Yong-jian.Replacement of humeral head prosthesis for four-part proximal humeral fractures or fracture-dislocations[J].zhongguo gu shang / China J Orthop Trauma ,2008,21(5):387~389
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号