C7后路椎板螺钉固定解剖学可行性研究
摘要点击次数: 2463   全文下载次数: 1236   投稿时间:2009-11-20    
作者Author单位AddressE-Mail
曹进 CAO Jin 宁波市第六医院骨科,浙江 宁波 315040 Department of Orthopaedics,Ningbo No. 6 Hospital,Ningbo 315040,Zhejiang,China caojin111@163.com 
徐荣明 XU Rong-ming 宁波市第六医院骨科,浙江 宁波 315040 Department of Orthopaedics,Ningbo No. 6 Hospital,Ningbo 315040,Zhejiang,China  
仲肇平 ZHONG Zhao-ping 宁波市第六医院骨科,浙江 宁波 315040 Department of Orthopaedics,Ningbo No. 6 Hospital,Ningbo 315040,Zhejiang,China  
马维虎 MA Wei-hu 宁波市第六医院骨科,浙江 宁波 315040 Department of Orthopaedics,Ningbo No. 6 Hospital,Ningbo 315040,Zhejiang,China  
赵刘军 ZHAO Liu-jun 宁波市第六医院骨科,浙江 宁波 315040 Department of Orthopaedics,Ningbo No. 6 Hospital,Ningbo 315040,Zhejiang,China  
李明 LI Ming 宁波市第六医院骨科,浙江 宁波 315040 Department of Orthopaedics,Ningbo No. 6 Hospital,Ningbo 315040,Zhejiang,China  
期刊信息:《中国骨伤》2010年,第23卷,第4期,第282-284页
DOI:10.3969/j.issn.1003-0034.2010.04.014
基金项目:
中文摘要:

目的:测量C7椎板的解剖学参数,探讨C7后路椎板螺钉固定的可行性。

方法:用游标卡尺和量角器测量22具成人C7标本与椎板螺钉进钉技术相关的解剖学数据,指标包括椎板上、中、下部分的厚度(分别为T1、T2、T3),椎板高度(H),进钉点至椎弓根内侧壁及侧块外侧壁的距离(分别为L1、L2),椎板轴线与矢状面的夹角(α).

结果:椎板上部厚度(T1)平均为(4.30±0.27) mm;中部厚度(T2)平均为(5.32±0.27) mm,27%(6例)小于4.50 mm;下部厚度(T3)平均为(4.78±0.26) mm;椎板中下部厚度均大于4.50 mm;椎板高度(H)平均为(14.83±0.26) mm;进钉点至椎弓根内侧壁的距离(L1)平均为(26.99±0.48) mm;最长钉道长度(L2)平均(41.60±1.10) mm;椎板与矢状面夹角(α)平均(49.3±1.1)°。

结论:C7后路椎板螺钉固定是可行的,适用于多数患者(73%).与C7椎弓根螺钉技术相比,椎板螺钉技术更简单,神经血管损伤的可能性更低。
【关键词】解剖学  颈椎  椎板  骨折固定术
 
Anatomic study of the posterior laminar screw fixation on C7
ABSTRACT  

Objective: To measure anatomic data of laminar of C7 and evaluate the possibility of the placement of C7 laminar screw.

Methods: Twenty-two specimens of C7 were measured with an vernier caliper and a goniomete and finded out the anatomic data for prominent vertebra laminar screw placement. The indicators included the thickness of the superior,median and inferior part of C7 laminar(T1,T2,T3),the height of the laminar(H),the distance of the anchor point to the medial wall of C7 pedicle and the lateral wall of the lateral mass(L2,L2) and the angle between the axis of C7 lamina and sagittal plane(α).

Results: The mean thickness of superior part of C7 lamina(T1) was(4.30±0.27) mm,(5.32±0.27) mm in median part(T2) with 27%(6 cases)of specimens thickness less than 4.50 mm and(4.78±0.26) mm in inferior part(T7). Both median part and inferior part were thicker than 4.50 mm. The mean height of C7 laminar(H) was (14.83±0.26) mm. The distance from the laminar anchor point to the medial wall of C7 pedicle(L1) and the lateral wall of the lateral mass(L7) was (26.99±0.48) mm and (41.60±1.10) mm respectively. The mean angle between the axis of C7 laminar and sagittal plane(α) was (49.3±1.1)°。

Conclusion: It is feasible to place screw in C7 laminar and this technique can be applied in 73% of Chinese. Compared with C7 pedicle screw technique,this technique is simple with little risk to the nerve and vascular structures.
KEY WORDS  natomy  Cervical vertebrae  Lamina  Fracture fixation
 
引用本文,请按以下格式著录参考文献:
中文格式:曹进,徐荣明,仲肇平,马维虎,赵刘军,李明.C7后路椎板螺钉固定解剖学可行性研究[J].中国骨伤,2010,23(4):282~284
英文格式:CAO Jin,XU Rong-ming,ZHONG Zhao-ping,MA Wei-hu,ZHAO Liu-jun,LI Ming.Anatomic study of the posterior laminar screw fixation on C7[J].zhongguo gu shang / China J Orthop Trauma ,2010,23(4):282~284
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号