镍钛-聚髌器结合Herbert螺钉及钢缆治疗髌骨下极粉碎性骨折
摘要点击次数: 1982   全文下载次数: 1295   投稿时间:2012-12-21    
作者Author单位AddressE-Mail
汤洋 TANG Yang 第二军医大学附属长海医院创伤骨科, 上海 200433 Department of Orthopaedics, Changhai Hospital Affiliated to the Second Military Medical University, Shanghai 200433, China  
章云童 ZHANG Yun-tong 第二军医大学附属长海医院创伤骨科, 上海 200433 Department of Orthopaedics, Changhai Hospital Affiliated to the Second Military Medical University, Shanghai 200433, China  
付青格 FU Qing-ge 第二军医大学附属长海医院创伤骨科, 上海 200433 Department of Orthopaedics, Changhai Hospital Affiliated to the Second Military Medical University, Shanghai 200433, China  
张春才 ZHANG Chun-cai 第二军医大学附属长海医院创伤骨科, 上海 200433 Department of Orthopaedics, Changhai Hospital Affiliated to the Second Military Medical University, Shanghai 200433, China zhangchuncai@vip.sina.com 
张欣 ZHANG Xin 第二军医大学附属长海医院创伤骨科, 上海 200433 Department of Orthopaedics, Changhai Hospital Affiliated to the Second Military Medical University, Shanghai 200433, China  
王攀峰 WANG Pan-feng 第二军医大学附属长海医院创伤骨科, 上海 200433 Department of Orthopaedics, Changhai Hospital Affiliated to the Second Military Medical University, Shanghai 200433, China  
期刊信息:《中国骨伤》2013年,第26卷,第6期,第457-459页
DOI:10.3969/j.issn.1003-0034.2013.06.004
基金项目:
中文摘要:

目的: 分析镍钛-聚髌器结合Herbert螺钉及钢缆治疗髌骨下极粉碎性骨折的手术方法及疗效。

方法: 2008年3月至2010年6月,采用镍钛-聚髌器结合Herbert螺钉及钢缆治疗髌骨下极粉碎性骨折34例,男19例,女15例;年龄22~75岁,平均38.6岁。术后早期功能锻炼,同时定期随访,并对膝关节功能恢复进行评定。

结果: 所有患者获随访,时间7~20个月,平均13.5个月,所有骨折获得解剖复位。疗效评定按照Böstman等临床评分系统评分如下:总分28.43±2.34,其中优(28~30分)21例,良(20~27分)13例,差(<20分)0例。

结论: 镍钛-聚髌器结合Herbert螺钉及钢缆是治疗髌骨下极粉碎性骨折的有效方法,有较好的临床应用价值。
【关键词】外固定器  髌骨  骨折  骨折固定术
 
Application of Ni-Ti patellar concentrator combined with Herbert screw and wirerope for the treatment of comminuted patellar inferior pole fractures
ABSTRACT  

Objective: To evaluate the surgical techniques and clinical effect of Ni-Ti patellar concentrator combined with Herbert screw and wirerope in treating comminuted patellar inferior pole fractures.

Methods: From March 2008 to June 2010,34 patients with comminuted patellar inferior pole fracture were treated with Ni-Ti patellar concentrator combined with Herbert screw and wirerope. Of them,there were 19 males and 15 females with an average age of 38.6 years old(ranged from 22 to 75). Early functional exercise was guided postoperatively and the patients were regularly followed up and their outcomes were assessed.

Results: All patients were followed up with an average of 13.5 months (ranged,7 to 20). All fractures healed. According to Böstman Clinical Rating System,the average score was 28.43±2.34,and excellent results in 21 cases,good in 13 cases and no poor case.

Conclusion: Ni Ti patellar concentrator combined with Herbert screw and wirerope for the treatment of comminuted patellar inferior pole fracture is an effective method and of great value to clinical application.
KEY WORDS  External fixators  Patella  Fractures  Fracture fixation
 
引用本文,请按以下格式著录参考文献:
中文格式:汤洋,章云童,付青格,张春才,张欣,王攀峰.镍钛-聚髌器结合Herbert螺钉及钢缆治疗髌骨下极粉碎性骨折[J].中国骨伤,2013,26(6):457~459
英文格式:TANG Yang,ZHANG Yun-tong,FU Qing-ge,ZHANG Chun-cai,ZHANG Xin,WANG Pan-feng.Application of Ni-Ti patellar concentrator combined with Herbert screw and wirerope for the treatment of comminuted patellar inferior pole fractures[J].zhongguo gu shang / China J Orthop Trauma ,2013,26(6):457~459
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号