目的:探讨应用带锁髓内钉治疗胫腓骨骨折,在不需X线引导下进行手术的可行性和效果。

方法:应用非扩髓带锁髓内钉治疗胫骨骨折46例。其中闭合性骨折25例,开放性骨折21例。改进带锁髓内钉远端瞄准器,增设辅助定位装置。

结果:全部病例经随访6个月以上,除1例骨折术后10个月愈合外,45例骨折愈合时间平均48个月。患者膝、踝关节功能均恢复正常。改进后的带锁髓内钉远端瞄准器,一次钻孔交锁成功45例,无锁钉放置失败,术后无髓内钉或锁钉断裂。

结论:非扩髓带锁髓内钉治疗胫腓骨骨折,手术不需X线引导,改进后的带锁髓内钉远端瞄准器,锁钉准确,简便实用。
【关键词】骨折固定术,髓内  腓骨  胫骨骨折
 
Improvement of the intramedullary interlocking nail with a distal screwing device for the treatment of fracture of the tibia
ABSTRACT  

Objective:To explore a method of treatment of fracture of the tibia using intramedullary interlocking nail improved with a distal screwing device

Methods:Forty six cases of fracture of the tibia were treated with the non reaming interlocking nail,which was improved with the distal localization and orientation devices.There were 25 cases of closed and 21 open fractures.

Results:The follow up period lasted for more than 6 months;45 cases had fracture union in an average of 4 8 months;one had delayed union.The functions of the knee and ankle joints resumed to their full extent.The insertion of the nails were successful at the first attempt and there was no complications.

Conclusion:Treatment of fracture of the tibia with the non reaming interlocking nail improved with the distal devices of localization and orientation is simple and effective.The treatment can be carried without the aid of X ray guidance.<
KEY WORDS  Fracture fixation,intramedullary  Fibula  Tibial fractures
 
引用本文,请按以下格式著录参考文献:
中文格式:邹育才,李佛保,洪湖强,曾润铭,邱松芝,刘梦璋,李光昭.胫骨带锁髓内钉治疗骨折与锁钉装置的改进[J].中国骨伤,2002,15(7):391~393
英文格式:ZOU Yu cai,LI Fo bao,HONG Hu qiang.Improvement of the intramedullary interlocking nail with a distal screwing device for the treatment of fracture of the tibia[J].zhongguo gu shang / China J Orthop Trauma ,2002,15(7):391~393
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号