髋臼位相参数的测定方法及临床意义
摘要点击次数: 1766   全文下载次数: 1161   投稿时间:2002-10-02  修订日期:2003-05-27  
作者Author单位AddressE-Mail
索鹏 SUO Peng 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
高建华 GAO Jianhua 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
梅汉尧 MEI Hanyao 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
陈永源 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
王浩杰 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
周永顶 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
陈坚 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
杨益 江门市五邑中医院暨南大学医学院第六附属医院,广东 江门 529000 Department of Orthopaedics, Wuyi TCM Hospital of Jiangmen Guangdong Jiangmen, 529000, China  
期刊信息:《中国骨伤》2003年,第16卷,第12期,第711-713页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:
中文摘要:

目的:探讨在髋关节正位X线片测量骨性髋臼前倾角、外展角的方法及对全髋关节置换手术(THR)中髋臼精确安置的指导意义。

方法:通过20具(40髋)骨盆标本髋关节正位X线片髋臼前倾角、外展角的测算值与骨盆标本髋臼前倾角、外展角的实际值相比较,以证明该测算方法的准确性。

结果:骨盆标本髋关节正位X线片测算的髋臼前倾角、外展角数值与实际值比较,其差异无显著性意义(P>0.05)。

结论:在髋关节正位X线片上测算髋臼前倾角、外展角的方法是准确客观的,该方法简单易行,从而使THR术中髋臼假体的安置更加精确。
【关键词】关节成形术,置换,髋  髋臼  放射测量术
 
The methods of accurate determination of acetabular phase parameters and their clinical significance
ABSTRACT  

Objective:To probe into the Methods for determination of the anteverted and abducted angel of osteo-acetabula,with positive radiographs of hip joints and significance for the accurate place for the acetabu-la in total hip replacement(THR).

Methods:Passing through the measurement of anteverted and abducted angels of acetabula in positive radiograms of 40 hip joints, compared with the practical values of anteverted and abducted angels of pelvis specimen,demonstrating the accurency of these kinds of measurement.

Results:There was no significant difference between the values of radiograms and that of the realities (P > 0.05).

Conclusion:The Methods for determination of anteverted and abducted angle of acetabula in the positive X-ray films of hip joints are accurate and objective,simple. This method is easy to be carried out for much more accurate replacement for the acetabular prosthesis in THR operation.
KEY WORDS  Arthroplasty, replacement, hip  Acetabulum  Radiometry
 
引用本文,请按以下格式著录参考文献:
中文格式:索鹏,高建华,梅汉尧,陈永源,王浩杰,周永顶,陈坚,杨益.髋臼位相参数的测定方法及临床意义[J].中国骨伤,2003,16(12):711~713
英文格式:SUO Peng,GAO Jianhua,MEI Hanyao.The methods of accurate determination of acetabular phase parameters and their clinical significance[J].zhongguo gu shang / China J Orthop Trauma ,2003,16(12):711~713
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号